scholarly journals The development of a World Health Organisation international standard for islet cell antibodies: the aims and design of an international collaborative study

Author(s):  
Anthony R. Mire-Sluis ◽  
Rose Gaines Das ◽  
Åke Lernmark
1990 ◽  
Vol 64 (02) ◽  
pp. 267-269 ◽  
Author(s):  
A B Heath ◽  
P J Gaffney

SummaryAn International Standard for Streptokinase - Streptodomase (62/7) has been used to calibrate high purity clinical batches of SK since 1965. An international collaborative study, involving six laboratories, was undertaken to replace this standard with a high purity standard for SK. Two candidate preparations (88/826 and 88/824) were compared by a clot lysis assay with the current standard (62/7). Potencies of 671 i.u. and 461 i.u. were established for preparations A (88/826) and B (88/824), respectively.Either preparation appeared suitable to serve as a standard for SK. However, each ampoule of preparation A (88/826) contains a more appropriate amount of SK activity for potency testing, and is therefore preferred. Accelerated degradation tests indicate that preparation A (88/826) is very stable.The high purity streptokinase preparation, coded 88/826, has been established by the World Health Organisation as the 2nd International Standard for Streptokinase, with an assigned potency of 700 i.u. per ampoule.


2016 ◽  
Vol 54 (9) ◽  
pp. 1467-1472 ◽  
Author(s):  
Susan J. Thorpe ◽  
Peter Rigsby ◽  
Graham Roberts ◽  
Anne Lee ◽  
Malcolm Hamilton ◽  
...  

AbstractBackground:Investigation of possible B12 and folate deficiencies requires measurement of these vitamins in serum. There is evidence that holotranscobalamin (holoTC), the active portion of B12 available to cells, is a more specific marker of early B12 deficiency than total B12. The availability of immunoassays for holoTC prompted an international collaborative study to assign a holoTC value to the World Health Organization (WHO) 1st International Standard (IS) for vitamin B12 and serum folate, 03/178.Methods:The IS, 03/178, and three serum samples with different holoTC levels were assayed by 12 laboratories in eight countries using manual and automated immunoassays for holoTC; one laboratory additionally performed an in-house assay. Fourteen sets of data were analysed.Results:Overall, the IS, 03/178, and the three serum samples demonstrated assay linearity and parallelism. An overall geometric mean (GM) holoTC value of 106.8 pmol/L was obtained for 03/178, with an inter-laboratory geometric coefficient of variation (GCV) of 10.5%. There was a reduction in inter-laboratory variability when the holoTC levels in the serum samples were determined relative to the IS with an assigned holoTC value rather than to the assays’ calibration. Accelerated degradation studies showed that 03/178 was sufficiently stable to serve as an IS for holoTC.Conclusions:The WHO Expert Committee on Biological Standardization endorsed the proposal to assign a holoTC value of 107 pmol/L to 03/178, corresponding to 0.107 pmol per ampoule, for use as the 1st IS for vitamin B12, serum folate, and holoTC.


2008 ◽  
Vol 16 (3) ◽  
pp. 303-311 ◽  
Author(s):  
Dorothy Xing ◽  
Carl Heinz Wirsing von König ◽  
Penny Newland ◽  
Marion Riffelmann ◽  
Bruce D. Meade ◽  
...  

ABSTRACT Enzyme-linked immunosorbent assay (ELISA) has been widely used to evaluate antibody responses to pertussis vaccination and infection. A common reference serum is essential for the standardization of these assays. However, no internationally recognized reference serum is available. At the request of the Expert Committee on Biological Standardization (ECBS) of the World Health Organization (WHO), a set of four candidate international standards has been prepared. These candidate materials have been assessed for suitability and compared to the widely used U.S. reference pertussis antiserum (human) lot 3, lot 4, and lot 5 by 22 laboratories from 15 countries in an international collaborative study. Laboratories measured immunoglobulin G (IgG) and IgA antibodies to pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), and fimbriae (Fim2&3) using their established immunoassays. The results of this study showed each of the four candidates to be suitable as an international standard. With the agreement of the participants, a recommendation has been made to the ECBS that the candidate material coded 06/140 be established as the First International Standard for pertussis antiserum (human), with the following assigned international units (IU): IgG anti-PT, 335 IU/ampoule; IgA anti-PT, 65 IU/ampoule; IgG anti-FHA, 130 IU/ampoule; IgA anti-FHA, 65 IU/ampoule; IgG anti-PRN, 65 IU/ampoule; and IgA anti-PRN, 42 IU/ampoule. No formal units have been proposed for anti-Fim2&3 because most assays used a mixture of fimbrial antigens. In addition, the candidate material coded 06/142 has been proposed as a WHO working preparation for characterization of assay systems.


1992 ◽  
Vol 67 (04) ◽  
pp. 424-427 ◽  
Author(s):  
P J Gaffney ◽  
A B Heath ◽  
J W Fenton II

SummarySince 1975 an International Standard for Thrombin of low purity has been used. While this standard was stable and of value for calibrating thrombins of unknown potency the need for a pure a-thrombin standard arose both for accurate calibration and for precise measurement of thrombin inhibitors, notably hirudin. An international collaborative study was undertaken to establish the potency and stability of an ampouled pure a-thrombin preparation. A potency of 97.5 international units (95% confidence limits 86.5-98.5) was established for the new a-thrombin standard (89/ 588) using a clotting-assay procedure. Stability data at various elevated temperatures indicated that the standard could be transported and stored with no significant loss of potency.Ampoules of lyophilised a-thrombin (coded 89/588) have been recommended as an International Standard for a-thrombin with an assigned potency of 100 international units per ampoule by the International Society for Thrombosis and Haemostasis (Thrombin and its Inhibitors Sub-Committee) in Barcelona, Spain in July 1990 while the Expert Committee on Biological Standardisation and Control of the World Health Organisation will consider its status at its next meeting in Geneva in 1991.


1984 ◽  
Vol 52 (02) ◽  
pp. 148-153 ◽  
Author(s):  
D P Thomas ◽  
A D Curtis ◽  
T W Barrowcliffe

SummaryAn international collaborative study, in which 22 laboratories participated, was carried out to establish a replacement for the International Standard for Heparin. A total of 248 assays were analyzed, including APTT, thrombin inhibition and anti-Xa assays, as well as pharmacopoeial assays. Overall, there was less than 5% difference in the mean potency estimates of the candidate preparations, by all assay methods. The freeze-dried preparation 82/502 demonstrated the closest parallelism by bioassay to the existing standard and was established by WHO as the 4th International Standard for Heparin, with an assigned unitage of 1780 i.u. per ampoule.


Sign in / Sign up

Export Citation Format

Share Document